Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The glare on the metal surface hides the scratch: how the polarizer in a handheld digital microscope reveals what a loupe and the eye missShiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to recordVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The glare on the metal surface hides the scratch: how the polarizer in a handheld digital microscope reveals what a loupe and the eye missShiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to record

Peak CPV-II-50 Color Analysis Loupe 50× with 0.02 mm Scale: When the Cyan Screen on a Print Production Must Have an Exact 175 lpi Line Screen and a Dot Diameter of 30 μm ±3 μm

Published July 8, 2026 at 20:07

Graphic print production is one of the most demanding industry sectors for optical QC. All color printing relies on the halftone screen principle — individual small color dots of varying size and density create the illusion of continuous color. Quality printing at 150-175 lpi (lines per inch) has dots with a diameter between 20 and 80 μm, tightly packed at standardized screen angles (typically Cyan 15°, Magenta 75°, Yellow 0°, Black 45°). A printing error of 5-10 μm in dot diameter can appear as a color shift in final inspection. An error of 1° in screen angle can cause moiré patterns. Verifying these parameters visually requires 50× magnification with a built-in microscopic scale.

What the Peak CPV-II-50 is

Color analysis loupe Beta CPV-II-50. 50x magnification is a specialized graphic color analysis loupe from Peak Optics. The instrument:

  • Has 50× magnification — the highest magnification in the CPV series.
  • Has a built-in 0.02 mm graduation scale (corresponding to 20 μm precision).
  • Has a 2 mm field of view and 1.6 mm measuring length.
  • Has an 11.7 mm working distance.
  • Has a 14.9 mm focal length.
  • Has a 0.18 numerical aperture (NA).
  • Has a focusable lens and focusable scale.
  • Has an inverted image (mirror-flip, standard for microscope optics).
  • Can be combined with the Peak 2008 series portable microscope via an adapter for color separation analysis.
  • Comes with a carrying case and standard scale included.

Basic specifications:

  • Manufacturer: Peak Optics (Japan)
  • Model: Beta CPV-II-50
  • Magnification: 50×
  • Field of view: 2 mm
  • Measuring length (scale): 1.6 mm
  • Scale graduation: 0.02 mm
  • Working distance: 11.7 mm
  • Focal length: 14.9 mm
  • Numerical aperture: 0.18
  • Dimensions: 150 × 45 × 145 mm
  • Weight: 415 g
  • Image orientation: Inverted (microscope standard)
  • Supplied in: Carrying case

Peak CPV-II-50 färg-analys-lupp 50× med 0,02 mm skala

Halftone screens in print production

Traditional offset printing and digital printing use halftone screens to simulate continuous color with just four printing inks (CMYK):

  • Cyan: Screened at a 15° angle (standard).
  • Magenta: 75° angle.
  • Yellow: 0° angle (the exception — placed horizontally).
  • Black: 45° angle.

The four screens are offset 15° from each other to avoid pattern interference (moiré). Yellow is exempted because the yellow dot is visually the least prominent.

Density is measured in lpi (lines per inch):

  • 85 lpi: Coarse newspapers, lithography.
  • 133 lpi: Standard magazines and catalogs.
  • 150 lpi: Quality printing, art books.
  • 175 lpi: Premium magazines, packaging printing.
  • 200+ lpi: High-quality photography catalogs.

At 175 lpi, the screen line spacing is 25.4 / 175 = 0.145 mm = 145 μm. Dot size varies from 15-20 μm (10% density, ”highlights”) to 100-120 μm (90% density, ”shadows”). The CPV-II-50’s 0.02 mm scale matches exactly the required precision.

Measurements with the CPV-II-50 scale

The scale in the loupe’s focal plane is overlaid on the printed surface. The operator can:

  • Measure dot diameter: Direct reading in 0.02 mm steps.
  • Count screen lines per division: With a known division (0.02 mm), lpi can be calculated.
  • Verify screen angle: By comparing the direction of the dot distribution against the scale’s axis.
  • Check registration shift: If Cyan dots are offset 20 μm from Magenta dots, this is visible directly.
  • Confirm individual points: At font edges in printed documents, verify that the edge is sharp and straight.

Combination with the Peak 2008 portable microscope

The CPV-II-50 can be mounted with an adapter to the Peak 2008 series portable microscope. This combination provides:

  • Color separation analysis: Built-in filters to separate the four CMYK channels. The operator sees only Cyan dots, then only Magenta, and so on.
  • Precision dot measurement: Individual dot diameter measured with sub-μm precision via the combination.
  • Reference photography: Some microscope models have a camera adapter for photographing screen patterns.

This functionality is especially valuable for print shops requiring ISO 12647 certification.

Where the CPV-II-50 makes a real difference

Commercial printing (offset, digital): Quality control of production printing. The ISO 12647 standard requires documented measurement.

Packaging printing: Carton, plastic, and label printing where print quality affects shelf appeal.

Newspaper and magazine production: Final QC of printed matter before distribution.

Photography and art printing: High-end reproduction of photos requiring precision.

Security printing (banknotes, passports, ID cards): Verification of microprint, security elements such as guilloche patterns.

Cartography and technical drawings: Precision printing where line thickness and clarity are critical.

Textile printing and sublimation printing: Digital printing on textiles where color accuracy is crucial.

Stamp and authenticity verification: Collector verification through detailed print analysis.

Education in graphic technology: Graphic technician training demonstrations.

Quality audit of supplier printing: Customer verification of print shops before placing production orders.

Numerical aperture (NA) and resolution

The Peak CPV-II-50 has NA = 0.18. This determines theoretical resolution according to Abbe’s law:

Resolution = 0.61 × λ / NA

At green light (λ = 550 nm): 0.61 × 550 / 0.18 = 1865 nm = 1.86 μm.

In practice: two dots closer than 2 μm appear as a single dot. At 50× magnification, 2 μm on the physical surface becomes 100 μm in the loupe’s field of view — clearly visible to the operator.

This resolution is sufficient for all graphic print analyses up to 300+ lpi. Sub-μm analysis would require high-NA objectives (0.4-0.9) with oil immersion, which is beyond the scope of a handheld loupe.

Inverted image — what it means

The CPV-II-50 has an ”inverted image” (reversed orientation). This is standard for microscope optics: the lens physically inverts the image so that up becomes down and left becomes right.

For the operator, this can be initially confusing. But the advantage: when the operator sees a print defect and needs to move the paper to inspect more dots, the movements become intuitive after a few minutes of experience. Move the paper to the left → the image in the loupe’s field of view moves to the right.

Alternative: an ”upright image” via an additional prism element. This would add 2-4 glass surfaces and reduce light transmission and contrast. Peak has chosen not to compensate for this, which provides better optical quality.

What you get for your money

Peak Optics Beta CPV-II-50 color analysis loupe, 50× magnification, 2 mm field of view, 1.6 mm measuring length, 0.02 mm scale graduation, 11.7 mm working distance, 14.9 mm focal length, 0.18 numerical aperture, focusable lens and focusable scale, inverted image orientation (microscope standard), dimensions 150×45×145 mm, 415 g weight, carrying case included, compatible with the Peak 2008 series portable microscope for color separation analysis.

10,213 kronor is the instrument investment. Compared to a general 50× loupe without graphic print calibration (2,000-5,000 kr, no built-in scale with 0.02 mm graduation), the premium is worthwhile for operators doing routine print QC. Compared to a desktop print microscope (30,000-100,000 kr), the CPV-II-50 is a handheld portable solution. For print shops with ISO 12647 certification, the instrument is a critical QC component.

Read more: Peak CPV-II-50 color analysis loupe in the shop →