Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The glare on the metal surface hides the scratch: how the polarizer in a handheld digital microscope reveals what a loupe and the eye missShiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to recordVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The glare on the metal surface hides the scratch: how the polarizer in a handheld digital microscope reveals what a loupe and the eye missShiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to record
Item number 43-AD4113T-I2V

Dino-Lite IR-LEDs 940nm + UV-LEDs 395nm, 1.3 Megapixels, Measuring Function

5.828 SEK

In stock

The AD4113T2V features both IR (~940 nm) and UV (~395 nm) LED illumination in a single unit.

Request a quote 43-AD4113T-I2V

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

Category: ,

Other models in the series 2

Description

The AD4113T-I2V features both IR (~940nm) and UV (~395nm) LED illumination in a single unit.


USBMag 10 2205 megapixelpreviewEDOFEDRAMRFLCFLCFLC


Multiple illumination options allow you to view magnified objects under normal external light sources such as white light or near IR, or under UV illumination, simply by switching from one to another.


IR can be used for document examination, and the new improved UV system provides enhanced fluorescence contrast for use in forensic, biomedical, or machine vision applications.


MAGNIFICATION WORKING DISTANCE FIELD OF VIEW (X) FIELD OF VIEW (Y) DEPTH OF FIELD
Listed values may vary slightly       Unit = mm
20 51.7 25.1 20.1 4
30 24.1 16.8 13.4 2
40 11.0 12.6 10.1 1.6
50 3.8 10.1 8.0 1.17
60 -0.6 8.4 6.7 –
200 -0.4 2.5 2.0 0.28
210 0.6 2.4 1.9 –
220 1.7 2.3 1.8 –
230 2.8 2.2 1.7 –


Lighting
Light/LED type ~395 nm UV + ~940 nm Infrared
Number of LEDs 4+4
LED switchable on/off: Yes
Infrared filter No
Diffuser available No
Emission filter No
Polarizer No
Optics
Magnification 10-50x 220x
Macro zoom No
Working distance Standard
Lens type Glass with anti-reflection coating
Sensor
Sensor type CMOS
Resolution 1.3 megapixel (1280×1024)
Maximum frame rate 30 fps
Compatibility
Interface USB 2.0
Operating System Windows 7, 8, 10 and 11, MacOS 10.9 and later
Software DinoCapture 2.0 (Windows), DinoXcope (Mac OS)
Supported Image Formats (Windows) BMP, GIF, PNG, JPG, TIF, RAS, PNM, TGA, PCX, MNG, WBMP, JP2, JPC, PGX
Supported Video Formats (Windows) WMV, FLV, SWF
Supported Image Formats (MacOS) JPEG, PNG
Supported Video Formats (MacOS) MOV
Image Standards DirectShow, UVC
Wifi Wireless ready, requires WF-10 WiFi-streamer (optional)
Housing
Housing Material Composite/plastic housing
Magnification Lock Yes
Dimensions 10.5 cm (L) x 3.2 cm (W)
Weight 105 g
Cable Length 1.8 m
Features
Special Function No
Measurement Yes
Calibration Yes
Microtouch Sensor Yes
ESD Safe No
Information
Package Contents Microscope, carrying bag, calibration target, ZT-Z-CC1 lens cover, user manual
Warranty Information 2-year European warranty
Certification CE, FCC, ROHS
Additional information
Connection

Focal Distance

Lighting

Product type

Magnification

Resolution

Specification

The AD4113T-I2V features both IR (~940nm) and UV (~395nm) LED illumination in a single unit.


USBMag 10 2205 megapixelpreviewEDOFEDRAMRFLCFLCFLC


Multiple illumination options allow you to view magnified objects under normal external light sources such as white light or near IR, or under UV illumination, simply by switching from one to another.


IR can be used for document examination, and the new improved UV system provides enhanced fluorescence contrast for use in forensic, biomedical, or machine vision applications.


MAGNIFICATION WORKING DISTANCE FIELD OF VIEW (X) FIELD OF VIEW (Y) DEPTH OF FIELD
Listed values may vary slightly       Unit = mm
20 51.7 25.1 20.1 4
30 24.1 16.8 13.4 2
40 11.0 12.6 10.1 1.6
50 3.8 10.1 8.0 1.17
60 -0.6 8.4 6.7 –
200 -0.4 2.5 2.0 0.28
210 0.6 2.4 1.9 –
220 1.7 2.3 1.8 –
230 2.8 2.2 1.7 –


Lighting
Light/LED type ~395 nm UV + ~940 nm Infrared
Number of LEDs 4+4
LED switchable on/off: Yes
Infrared filter No
Diffuser available No
Emission filter No
Polarizer No
Optics
Magnification 10-50x 220x
Macro zoom No
Working distance Standard
Lens type Glass with anti-reflection coating
Sensor
Sensor type CMOS
Resolution 1.3 megapixel (1280×1024)
Maximum frame rate 30 fps
Compatibility
Interface USB 2.0
Operating System Windows 7, 8, 10 and 11, MacOS 10.9 and later
Software DinoCapture 2.0 (Windows), DinoXcope (Mac OS)
Supported Image Formats (Windows) BMP, GIF, PNG, JPG, TIF, RAS, PNM, TGA, PCX, MNG, WBMP, JP2, JPC, PGX
Supported Video Formats (Windows) WMV, FLV, SWF
Supported Image Formats (MacOS) JPEG, PNG
Supported Video Formats (MacOS) MOV
Image Standards DirectShow, UVC
Wifi Wireless ready, requires WF-10 WiFi-streamer (optional)
Housing
Housing Material Composite/plastic housing
Magnification Lock Yes
Dimensions 10.5 cm (L) x 3.2 cm (W)
Weight 105 g
Cable Length 1.8 m
Features
Special Function No
Measurement Yes
Calibration Yes
Microtouch Sensor Yes
ESD Safe No
Information
Package Contents Microscope, carrying bag, calibration target, ZT-Z-CC1 lens cover, user manual
Warranty Information 2-year European warranty
Certification CE, FCC, ROHS
PDF (1)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *