Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch on the part is 0.2 mm or 0.4 mm, and you only see it when the lighting and the scale are in the same magnifierShiny metal surfaces become measurable when the glare disappears and the magnification is saved in the imageHow to Measure a Scratch on Shiny Metal When Reflections Hide the EdgeMeasure on site what the eye can only guess: edge wear and groove width at 300x magnificationHow Big Is the Scratch, Really? Measure Directly on the Part with a Zoom LoupeMeasure Scratches and Solder Joints on Screen Without Touching the Sample with Fingers or ToolsShiny Metal Surfaces Only Reveal Their Flaws When the Light Comes Straight Through the OpticsGlossy and uneven surfaces can be measured when the microscope stacks both focus and exposureWhy the Scratch in the Chrome Surface Only Shows Up When the Light Comes Through the LensHow to Measure and Document Shiny Surfaces Without Sending the Part to the LaboratoryVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The scratch on the part is 0.2 mm or 0.4 mm, and you only see it when the lighting and the scale are in the same magnifierShiny metal surfaces become measurable when the glare disappears and the magnification is saved in the imageHow to Measure a Scratch on Shiny Metal When Reflections Hide the EdgeMeasure on site what the eye can only guess: edge wear and groove width at 300x magnificationHow Big Is the Scratch, Really? Measure Directly on the Part with a Zoom LoupeMeasure Scratches and Solder Joints on Screen Without Touching the Sample with Fingers or ToolsShiny Metal Surfaces Only Reveal Their Flaws When the Light Comes Straight Through the OpticsGlossy and uneven surfaces can be measured when the microscope stacks both focus and exposureWhy the Scratch in the Chrome Surface Only Shows Up When the Light Comes Through the LensHow to Measure and Document Shiny Surfaces Without Sending the Part to the Laboratory

The scratch on the part is 0.2 mm or 0.4 mm, and you only see it when the lighting and the scale are in the same magnifier

Published 28 November 2026 at 20:50

It happens in most workshops and quality departments: a part lies under a fluorescent light fixture, someone says the scratch is too deep, someone else says it is within tolerance, and in the end a folding ruler or an old magnifier without a scale is fetched. Without proper lighting and without a scale, the assessment becomes a matter of opinion, and then either too much or too little gets rejected.

Mätlupp med LED-belysning med 9 skalor. Förstoring 10x

What it is

The KIMAG-10 is a focusable measuring magnifier with 10x magnification and a ring of eight LEDs around the lens. The optics are achromatic, meaning corrected for chromatic aberration, and the lenses are anti-reflective coated. The image is distortion-free all the way out to the edge of the field of view, which matters when you are measuring and not just looking. The scale is made of glass with 0.1 mm graduation. The working distance is 30 mm and the field of view is 34 mm. Nine reticle scales are included, and more can be purchased and swapped in. Batteries and a gift box are included.

What problems it solves

Two things most often ruin a visual inspection: poor light and a lack of reference. The ring-shaped LED lighting gives even, high-contrast illumination without shadows from your own hand or head. The scale sits in the same field of view as the part, so you read the dimension directly instead of comparing it with a memory of how big something looked. With different scales you can also measure line width, diameter or radius, or compare against known patterns, depending on which scale you insert.

When it is used

It is used in incoming inspection, during ongoing production and for troubleshooting out at the machine. Because it is handheld, it goes to the part and not the other way around.

Three practical examples

Machine shop. Checking burrs after milling, edge breaks and scratches on sealing surfaces. You see immediately whether a defect is within what the drawing allows and can make a decision at the machine.

Electronics. Assessing solder joints, trace widths and the spacing between pads on circuit boards. The ring light reduces reflections from solder and lacquer, and a suitable scale helps you see whether a distance actually falls below the requirement.

Food production. Checking print and seals on packaging, as well as estimating the size of foreign particles found on the line. It does not replace a laboratory, but it provides an initial basis for deciding whether a batch needs to be stopped.

Why it pays off

The price is on par with a couple of basic hand tools, whereas the cost of a misjudgment is a rejected part, a complaint or unnecessary downtime. By measuring on site, you avoid sending parts to the measuring room for questions that can be answered in a minute. If you need to demonstrate traceability during an audit, a calibration certificate is available as an option, with code S-9183-PP.

For anyone who currently makes their assessments with the naked eye or a magnifier without a scale, the step is short, and the benefit is noticeable already in the first week.

Read more