Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Shiny metal surfaces become measurable when the glare disappears and the magnification is saved in the imageHow to Measure a Scratch on Shiny Metal When Reflections Hide the EdgeMeasure on site what the eye can only guess: edge wear and groove width at 300x magnificationHow Big Is the Scratch, Really? Measure Directly on the Part with a Zoom LoupeMeasure Scratches and Solder Joints on Screen Without Touching the Sample with Fingers or ToolsShiny Metal Surfaces Only Reveal Their Flaws When the Light Comes Straight Through the OpticsGlossy and uneven surfaces can be measured when the microscope stacks both focus and exposureWhy the Scratch in the Chrome Surface Only Shows Up When the Light Comes Through the LensHow to Measure and Document Shiny Surfaces Without Sending the Part to the LaboratoryReflections on shiny surfaces cause defects to be missed: how to see through the glare during microscopic inspectionVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Shiny metal surfaces become measurable when the glare disappears and the magnification is saved in the imageHow to Measure a Scratch on Shiny Metal When Reflections Hide the EdgeMeasure on site what the eye can only guess: edge wear and groove width at 300x magnificationHow Big Is the Scratch, Really? Measure Directly on the Part with a Zoom LoupeMeasure Scratches and Solder Joints on Screen Without Touching the Sample with Fingers or ToolsShiny Metal Surfaces Only Reveal Their Flaws When the Light Comes Straight Through the OpticsGlossy and uneven surfaces can be measured when the microscope stacks both focus and exposureWhy the Scratch in the Chrome Surface Only Shows Up When the Light Comes Through the LensHow to Measure and Document Shiny Surfaces Without Sending the Part to the LaboratoryReflections on shiny surfaces cause defects to be missed: how to see through the glare during microscopic inspection

Shiny metal surfaces become measurable when the glare disappears and the magnification is saved in the image

Published 28 November 2026 at 00:42

Many people who have tried to inspect a ground shaft journal or a solder joint under ordinary microscope lighting will recognize this: the surface glares, the details drown in a white reflection, and the image is unusable in a nonconformance report. And when you later need to measure on the image, it is easy to no longer know exactly which magnification applied when it was taken.

Dino-Lite EDGE PLUS, 1,3 Mpixels, mätfunktion, automatisk förstoringsavläsning, polarisator, metall

A handheld digital microscope for shiny surfaces

The Dino-Lite EDGE PLUS (AM4517MZT) is a USB microscope with 1.3 megapixels, 30 frames per second and magnification from 20x to 220x. It comes in a compact metal housing and has eight white LEDs that can be switched on and off. Two features set it apart from simpler models. The first is a built-in linear polarizer that removes unwanted glare from shiny surfaces. The second is AMR, automatic magnification reading, which registers the magnification and saves it together with the image.

Which problems it solves

The polarizer lets you rotate the glare away and see the real surface structure, for example machining marks, scratches or pores. With AMR you no longer have to note down the magnification by hand. Measurements in the DinoCapture 2.0 software are based on the correct scale, which reduces the risk of a length or diameter result being wrong simply because someone forgot which position the wheel was set to. In addition, a diffuser (N3C-D) is included for surfaces that would otherwise produce harsh shadows.

Three situations where it makes a difference

Machining industry. During incoming or final inspection of milled and ground parts, you can assess burrs, edge damage and surface finish without sending the part to a measurement room. The image and the measurement are included in the documentation.

Electronics. Solder joints and component leads on circuit boards are shiny and difficult to assess under direct light. With the polarizer, cold solder joints, bridges and cracks are easier to see, and they can be measured directly on the image.

Maintenance and installation. Sealing surfaces on valves, couplings and pipe joints can be checked on site for damage that causes leaks. The microscope is handheld and connects to a laptop, so it goes to the machine rather than the other way around.

Why it pays off

The cost of a misjudged surface is rarely the microscope itself. It lies in a scrapped batch, a complaint or a stoppage that could have been avoided with a clear image at the right scale. When the same tool delivers a sharp image, good contrast and traceable magnification, inspection goes faster, and the decision can be shown to a customer or auditor. It also reduces the need for external analyses for routine questions.

Next steps

If you often inspect shiny metal surfaces or need measurable images that can be documented, this is a model worth a closer look. Specifications, field of view and working distance for each magnification are available on the product page.

Read more

More news

All news