Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Shiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to recordShiny metal surfaces hide defects behind reflections – here’s how to see them anyway at the benchVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Shiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to recordShiny metal surfaces hide defects behind reflections – here’s how to see them anyway at the bench

Dino-Lite AM3713TB Strobe LED Microscope: How a Microsecond-Long Light Flash Freezes a Spinning Motor Shaft So Bearing Edges Look Still Under the Microscope

Published July 12, 2026 at 02:16

A quality technician at a glass bottle manufacturing plant has a problem: the products travel past the inspection station at 2 m/s. Each bottle passes the microscope in 30 milliseconds. With a normal microscope setup, they see only a SMEAR — the bottle’s surface is blurred across the entire field of view. Inspecting for microscopic defects (bubbles, cracks, irregularities in the molded glass) is impossible with continuous illumination.

The solution: STROBOSCOPIC illumination. The LEDs are not lit continuously but in very short pulses synchronized with the camera’s image frames. Each pulse is so short (~20 μs) that the bottle has moved only 0.04 mm during the exposure. In the image, the bottle appears STATIONARY — even though it is physically moving at 2 m/s. The quality of the inspection is the same as if the product were standing still.

Motion blur: fundamental photographic physics

Every camera image is a TIME INTEGRAL. During the exposure time, the sensor elements accumulate photons. If the object moves during the exposure, the same image point lands on different sensor elements over the course of the exposure — the result is a smeared image.

Quantitatively, the motion blur length L (in pixels or millimeters in the field of view) is:

L = v × T_exp × M

Where:

  • v = the object’s speed.
  • T_exp = exposure time.
  • M = magnification (total, for the microscope).

In microscopy, M is typically 10-200x. This multiplies the motion blur considerably compared with normal photography.

A concrete example: conveyor belt with v=2 m/s, magnification M=50x, standard camera exposure time T_exp = 16 ms (1/60 sec, standard rate). Motion blur in sensor coordinates: 2 × 0.016 × 50 = 1.6 meters! In the microscope image this shows up as total blur — nothing is discernible.

The stroboscope solution

Stroboscopic illumination eliminates motion blur by SHORTENING the effective exposure time. The ideal principle:

  1. The camera’s electronic shutter is open for 16 ms (1/60 sec).
  2. But the LEDs are NOT lit the whole time. They light up only in a short flash (typically 5-50 μs).
  3. During the remaining 15.95 ms of the camera’s exposure, the scene is in darkness. No image information is recorded.
  4. Effective exposure time = the duration of the LED flash, not the time the camera shutter is open.

For this to work, the ambient lighting MUST be low. If there is a lot of ambient light, it fills the scene during the entire time the camera shutter is open, and the motion blur returns.

This is why the AM3713TB specifically states: ”works best with lighting below 20 lux and is not effective above 80 lux”. Under normal office lighting (500+ lux), the stroboscopic technique does not work — the object must be shielded from ambient light (e.g., in an enclosure or dark cabin).

Calculating the stroboscope’s effectiveness

Using the same example as above, but now with a stroboscope: v=2 m/s, M=50x, T_flash = 20 μs.

Motion blur = 2 × 0.00002 × 50 = 0.002 meters = 2 mm.

From 1.6 m of blur down to 2 mm of blur — an 800x improvement. With a microscope field of view of 10-20 mm, this is entirely acceptable for most inspection applications.

Even shorter flashes are possible: 5 μs gives 0.5 mm of blur, enabling high-precision measurement even on fast-moving products.

Dino-Lite Premier AM3713TB USB microscope with stroboscopic LEDs

Synchronization: the tricky part

If the stroboscope flash fires at a random time, there is a risk that the camera shutter is closed during the flash — in which case no image is exposed. Or the flash may fire during the frame change — in which case two half images are exposed.

The solution: SYNCHRONIZATION between the LEDs and the camera. The AM3713TB has built-in electronics that:

  1. Read the camera’s exposure signal.
  2. At the START of the exposure, fire the stroboscopic flash within a few microseconds.
  3. The flash is completely finished LONG BEFORE the shutter closes.
  4. The sensor elements then have time left to read out the image data and transfer it before the next cycle.

This is built into the instrument’s firmware. The operator sees only the on/off switch for stroboscope mode.

Frequency and matching to the object

The AM3713TB has a 60 fps frame rate. The LEDs light up 60 times per second. What happens if the object’s motion frequency matches this?

Suppose a shaft rotates 60 revolutions per second (3,600 rpm). At 60 fps, the stroboscope lights the LEDs once per shaft revolution. If the timing is right, the light always fires when the shaft is in EXACTLY THE SAME rotational position. Result: the shaft looks COMPLETELY STATIONARY in the microscope, like a photographic stop-motion.

At 60.5 rev/s (3,630 rpm), the light fires slightly earlier on each revolution → the shaft appears to rotate SLOWLY backward at 0.5 rev/s (30 rpm) in the microscope.

This optical illusion is the same reason old films show car wheels that appear to rotate backward at certain speeds — a SAMPLING ARTIFACT. In microscope applications this is USEFUL — you can visually check the condition of a bearing edge on a spinning motor or gear without stopping the machinery.

60 fps maximum frame rate

60 fps is the limit for the AM3713TB. This is four times faster than the usual 15-25 fps of most USB microscopes. Practical consequences:

  • Real-time inspection without the object blurring in the image due to digital smearing.
  • Rapid analysis of transient events (failing components, high-speed motor faults).
  • Video recording for later analysis of fast processes.

However, the image resolution is VGA (640×480). This is LOWER than most modern microscopes (which have 1.3-5 MP). The trade-off: a high frame rate requires a lower pixel count for the USB 2.0 bandwidth to suffice. USB 3.0 would allow both, but the Dino-Lite AM3713TB is USB 2.0.

Applications

Production line QC: Fast conveyor belts where every product must be inspected without stopping the belt. Food packaging, electronics assembly, pharmaceutical packaging.

Printing industry: Roll-to-roll printing can run at 50-100 m/min. Stroboscopic inspection shows print quality, color registration and defects while the web is moving.

Textile production: Weaving faults, thread breaks and fabric defects can be detected without stopping the loom.

Motor shaft and gear inspection: Visual inspection during operation to detect signs of wear.

Turbine and propeller inspection: Spinning blades can be viewed as ”stationary” with a stroboscope.

Vibration analysis: Vibrating objects can be viewed at specific oscillation positions with the right frequency matching.

Bio-observation: Fast-moving microorganisms in aquariums or cultures.

Plastics manufacturing: Injection-molded plastic that is still moving as it leaves the mold.

Limitations

  • Requires a dark environment: Ambient lighting above 80 lux makes the stroboscopic technique ineffective. The instrument is not suited for outdoor use or brightly lit rooms.
  • Low resolution (VGA): 640×480 is sufficient for general inspection but not for high-precision measurement.
  • Fixed frame rate (60 fps): The instrument cannot be synchronized with external frequency signals. Frequency matching must be at multiples of 60 Hz.
  • Limited to a 3-15 cm working distance: This is the effective range of the LEDs. Outside this range, the stroboscopic technique does not work.
  • No measurement function in stroboscope mode: Precision dimensional measurement requires high resolution, which conflicts with a high frame rate.

The physics lesson on persistence of vision

An interesting piece of side physics: when the stroboscopic LEDs light up in 20 μs flashes 60 times per second, the eye perceives this as CONTINUOUS ILLUMINATION. The reason: the retina of the eye has ”persistence of vision” — the nerve impulses from the photoreceptors are retained for ~50-100 ms before they are ”forgotten”. At a frequency of 60 Hz (16 ms between flashes), the eye never has time to forget the previous flash — resulting in the perception of continuous light.

This is the same effect that makes TVs, films and LED lamps with 50-60 Hz PWM control look stable to the eye even though they are flickering. Below 25 Hz, the flicker starts to become visible (the ”old film” look).

What you get for your money

Dino-Lite Premier AM3713TB USB microscope with stroboscopic LED illumination, 8 white LEDs with synchronized stroboscope function, 20 μs flash duration, 60 fps continuous frame rate, VGA 640×480 CMOS sensor, magnification 10-70x + 200x, working distance 3-15 cm (optimal for the stroboscopic effect), IR cut filter >650 nm, USB 2.0 connection, DinoCapture 2.0 software (Windows 7-11), AR-coated glass optics. 5,183 SEK.

A specialty tool for industrial inspection of fast-moving products, motor and gear condition, printing QC and other applications where motion blur prevents conventional microscopy. The combination of short LED flashes and a 60 fps frame rate provides BOTH image freezing AND real-time video playback. For inspection of small, fast-moving objects in dark environments, this is the economical sweet-spot instrument.

Read more: Dino-Lite AM3713TB stroboscopic microscope in the shop →

More news

All news