Hoppa till innehåll
Free shipping on orders over 3000 SEK excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The glare on the metal surface hides the scratch: how the polarizer in a handheld digital microscope reveals what a loupe and the eye missShiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to recordVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The glare on the metal surface hides the scratch: how the polarizer in a handheld digital microscope reveals what a loupe and the eye missShiny solder joints and uneven surfaces: how to get a measurable image without glare and blurry edgesLive Full HD Image Straight on the Screen: Skip the Computer When Inspecting Small DetailsThe measurement field no one sees: when magnification is entered by hand, the measurement goes wrongFrom suspected damage to a measurable image: a digital microscope that works with or without a computerSharp images and measurements on an uneven, glossy surface: how to solve what a magnifier and the naked eye can’tReflections hide the defect: how to inspect shiny metal and plastic surfaces without glareReflections in shiny metal hide the flaw: how to see the surface with polarized light and measure directly in the imageCrack magnifier with a stainless steel scale: how to tell whether the crack is 0.2 mm or 0.4 mmMeasurement errors in microscope images often start with a magnification that someone forgot to record

Dino-Lite EDGE AF4915-FJT with 940 nm IR Illumination: What You Can See with Invisible Light That Standard Lighting Misses

Published July 10, 2026 at 23:16

A document examiner in an insurance investigation is looking at a payment form. Two dates are written in different pens, but one of them appears to have been altered after the form was submitted. Under normal lighting, all the digits look equally dark. Under 940 nm infrared light, one series of digits disappears completely while the other remains visible — and beneath the vanished digits, the original numbers that were written first appear. A document forgery that had been invisible for months is now clearly visible on screen after 2 minutes under the microscope.

This is a clear example of how infrared light reveals what visible light cannot. The Dino-Lite EDGE AF4915-FJT is a USB microscope specifically designed for this type of work, with a 940 nm IR LED array as its illumination source.

Why 940 nm — the practically accessible IR band

Infrared light spans wavelengths from 700 nm (just beyond visible red) up to 1 mm (the microwave boundary). For microscopy, different sub-bands are relevant for different purposes:

  • NIR (Near Infrared) 700-1400 nm: This is where 940 nm falls. Standard CMOS sensors (the same as in your phone camera) are sensitive to this band without special modification. LED manufacturing is well established and inexpensive.
  • SWIR (Short-Wave Infrared) 1400-3000 nm: Requires InGaAs sensors (indium gallium arsenide). Significantly more expensive (cameras from 100,000+ SEK).
  • MWIR (Mid-Wave) 3-5 μm: Requires cooled MCT sensors. Mainly for thermal cameras, not microscopy.
  • LWIR (Long-Wave) 8-14 μm: The thermography band. Thermal cameras.

NIR at 940 nm is the sweet spot: far enough beyond visible light to reveal new optical effects, yet still within reach of standard CMOS sensor and LED technology. The AF4915-FJT uses this band because it’s the economic optimum for most industrial and forensic applications.

What 940 nm reveals that visible light misses

Every material has a unique spectral signature — how much light it reflects or absorbs at different wavelengths. This means materials that look identical in visible light can look completely different in IR. Concrete examples:

Carbon-based ink vs. iron gall ink: Carbon-based ink (modern pens, markers) is opaque in both visible and IR light. Iron gall ink (historical documents, certain security inks) is opaque in visible light but TRANSPARENT under 940 nm IR. Practical consequence: text written with iron gall ink over older text disappears under IR, revealing the underlying text.

Silicon defects: Crystalline silicon is TRANSPARENT at wavelengths above 1100 nm (bandgap wavelength) but also partially transparent at 940 nm. Sub-surface defects (microcracks, contamination inclusions) in silicon wafers or microchips are visible under 940 nm IR but not in visible light.

Sub-dermal veins: Hemoglobin in blood has different absorption in IR than in visible light. Veins a few millimeters beneath the skin are clearly visible under 940 nm illumination even when barely visible to the naked eye. Used clinically as an aid for intravenous injections.

Watermark detection: Paper watermarks (thin spots) and security watermarks (embedded fibers) react differently to IR than ordinary paper. Authentication of banknotes and genuine documents.

Moisture vs. watermark: Free water absorbs 940 nm much more strongly than dry paper. Moisture damage can be distinguished from watermarks in conservation analysis.

Polymer identification: Certain plastics (polyester, PET, PP) have a different IR signature than others (nylon, acrylic). Fast material identification for recycling or QC.

Certain classes of organic pigments: Some dark pigments become transparent under IR while others retain their opacity. Used in painting conservation (revealing underdrawings beneath the paint’s surface layer).

CMOS sensors ”see” 940 nm — but we don’t

Here’s the split that makes it work: the Dino-Lite’s CMOS sensor has high sensitivity to 940 nm light, BUT the human eye has practically zero sensitivity there. This combination is what makes IR microscopy possible:

  1. Your eye doesn’t see the 940 nm LEDs light up.
  2. The sensor sees them clearly.
  3. The screen converts the sensor’s IR signal into a visible black-and-white image.
  4. The operator sees the IR signal as a normal black-and-white image on screen.

This is different from thermal cameras (which display 8-14 μm heat radiation). The AF4915-FJT shows REFLECTED NIR — not emitted heat. The IR illumination comes from the instrument’s own LED array; the sensor captures what is reflected back.

About filters — and why the AF4915-FJT does NOT have an IR-block filter

Standard CMOS cameras (like your phone) have a built-in IR-BLOCK FILTER in front of the sensor. Reason: the ordinary sensor sees IR and would produce incorrect colors if IR light from the sun or lamps mixed with visible light. The filter blocks everything above ~700 nm.

The Dino-Lite AF4915-FJT has NO such filter. The sensor sees the entire 700-1000 nm range freely. When operating with the instrument’s IR LEDs on and the visible LEDs off, the sensor sees ONLY reflected IR light.

If you switch back to visible LEDs (the instrument has both IR LEDs and white LEDs that can be switched on independently), the image will be slightly less color-accurate than a standard CMOS due to the missing IR block. This is the only ”price” of IR functionality.

Dino-Lite EDGE AF4915-FJT 940 nm IR-LED mikroskop

Flexible LED Control (FLC)

The AF4915-FJT doesn’t just have a single IR LED — it has an LED array with FLEXIBLE LED CONTROL (FLC). This means the LEDs are arranged in FOUR QUADRANTS around the lens, and each quadrant can be switched on or off independently, with six intensity levels.

Practical implications:

  • One-sided illumination: Light up only one quadrant. Creates shadows that reveal 3D topography. Standard technique for spotting small surface irregularities.
  • Diagonal illumination: Light up two opposite quadrants. Reduces shadows from edges.
  • Ring illumination: Light up all four quadrants. Homogeneous, shadow-free view. Standard for most observation tasks.
  • Intensity adjustment: For reflective objects (metal, glossy plastic), intensity can be lowered to avoid overexposure.

Other features

Extended Depth of Field (EDOF): At low magnification, depth of field is measured in millimeters; at high magnification, it’s only micrometers. EDOF captures multiple images at different focus points and automatically stacks them. Result: images of 3D objects where the entire object is in sharp focus.

Extended Dynamic Range (EDR): Captures multiple images at different exposures and merges them. Critical for scenes with both very bright and very dark areas — e.g. a metal surface with black casting holes.

Automatic Magnification Reading (AMR): The instrument has a built-in sensor that reads the magnification the operator has selected via the focus ring. The software automatically measures objects at the correct scale without manually entering the magnification. Eliminates a key source of error in dimensional measurement.

Applications for the AF4915-FJT

Document forensics: Detection of ink overwrites, erasure traces, forged signatures. Torn documents from earlier stages.

Conservators and museums: Analysis of paintings for underdrawings, retouching, restoration testing. Has become a standard tool in conservation labs.

Electronics inspection: PCB defects beneath silicone coating. Wire-bond inspection under transparent encapsulation. Identification of cold solder joints.

Semiconductor QC: Sub-surface defects in silicon wafers. Chip-level inspection before packaging.

Conservation of archaeological artifacts: Writing on parchment or papyrus that has become illegible. IR can restore readability.

Water damage assessment: Detection of previous moisture damage on paper, textiles, wood products for conservation or insurance assessment.

Medical vein localization: Training scenarios for IV injection technique.

Forensic investigations: Detection of blood spatter on dark surfaces, ink analysis, document tampering.

Philatelic authentication: Detection of restored or fake stamps via IR signature analysis.

Art authentication: Signature verification, authenticity assessment of oil paintings.

Limitations

  • Reflectance microscopy only: Not transmission through the sample. For transparent samples (tissue sections, thin plastic films) a different instrument is needed.
  • No color information: 940 nm is a single wavelength. The image is black and white. If color analysis is needed, visible-light mode must be used separately.
  • Depth limitation: 940 nm penetrates 0.5-5 mm into biological tissue depending on type. For deeper penetration (10+ mm), a SWIR instrument is needed (much more expensive).
  • No auto-fluorescence: For fluorescence microscopy, UV or specific visible-LED models are needed (Dino-Lite has other variants for this).

What you get for the money

Dino-Lite EDGE AF4915-FJT USB microscope, 1.3 megapixel CMOS sensor, 940 nm IR LED array with Flexible LED Control (FLC) across four quadrants and six intensity levels, extra white LEDs for visible-light mode, 15-90x adjustable optical magnification, Extended Depth of Field (EDOF), Extended Dynamic Range (EDR), Automatic Magnification Reading (AMR), USB connection to PC, compatible with the WF-20 WiFi streamer for wireless operation, includes DinoCapture software. 9,889 SEK.

A specialized tool for document forensics, conservation, semiconductor QC, electronics inspection, and any other application where infrared light reveals what visible light cannot. The extra 3,000-5,000 SEK over a standard visible-light Dino-Lite pays for itself directly if IR microscopy is an integral part of your workflow. For general microscopy without IR needs, choose the standard variants. For deeper IR applications (SWIR, MWIR), significantly more expensive instruments are required.

Read more: Dino-Lite AF4915-FJT IR microscope in the shop →

More news

All news